+90 533 570 17 44 info@aykomsan.com.tr Pazartesi - Cuma: 09:00 - 18:00
Get a Quote Now

Ziya Gökalp Mah. Dağarcık Sok. No:35, 34490 Başakşehir/İstanbul

TR EN
Search Products
Concrete Cube Specimen Mould 150×150×150 mm - 1800-2000 g
NewDiscountFast Delivery
AYKOMSAN 150×150×150 mm 2200 g BMC beton küp numune kalıbı
Concrete Specimen Moulds

Concrete Cube Specimen Mould 150×150×150 mm - 1800-2000 g

AYKOMSAN KALIP Brand: AYKOMSAN KALIP

Hafif gövdeli BMC 15 cm beton numune kalıbı

Code: AY-BNK-150-2200 NewDiscountFast Delivery In Stock

A 1800-2000 g BMC composite mould for 150 mm concrete cube specimens, offering easier handling and compressed-air demoulding.

Get a Quote

We offer a clear, project-specific price for this product.

Request a Quote Now
Share:
TS EN 124-5 Certified
Lightweight & Easy Installation
Long-Lasting Composite
Rustproof & Corrosion-Free

AY-BNK-150-2200 concrete cube mould is a lighter BMC model for preparing 150 mm cube specimens. Its 1800-2000 g body is practical where several moulds are moved repeatedly between casting and curing areas.

Specimen size and reference

TS EN 12390-1 / EN 12390-1 is the primary reference for the shape and dimensions of hardened concrete test specimens. Confirm the required geometry in the project specification.

  • Size: 150×150×150 mm
  • Code: AY-BNK-150-2200
  • Weight: 1800-2000 g
  • Material: BMC composite

Handling and demoulding

The lighter body supports frequent handling. Hardened specimens can be released by controlled compressed air through the inlet. Regular cleaning helps preserve surface quality and dimensional consistency.

  • Easy transport
  • Compressed-air release
  • Impact- and wear-resistant body

Choosing between 1800-2000 g and 2800 g

Both products target the same specimen size. Choose according to handling preference, daily casting volume and the desired body weight. The 2800 g model is the heavier alternative.

Reliable results in practice

Specimen mould selection is only one part of the concrete or mortar testing workflow. Comparable results also require representative sampling, correct placing and compaction, clear specimen identification and curing under the conditions required by the applicable procedure. Inspect the mould before use. Hardened residue, cracks, severe wear or visible distortion should trigger cleaning, dimensional verification or replacement. On products designed for compressed-air release, keep the inlet clear and apply pressure gradually; do not force the specimen with impact tools. Before purchase, confirm the product code, internal dimensions, body weight and material in writing. This prevents confusion between products that have similar names but different geometries. Where the laboratory quality system requires it, verify internal dimensions at planned intervals with suitable measuring equipment and retain the inspection records. The current project specification and the latest edition of the referenced test standard always take precedence over general product information.

Quotation and technical support

Compare the 2800 g model or request a quotation for the 2200 g mould.

SSS

Frequently Asked Questions

Why do concrete specimen mould prices vary?+

<p><strong>Short answer:</strong> Why do concrete specimen mould prices vary? should be answered by checking the current project specification, the referenced test method and the exact mould data. Product selection should consider specimen geometry, target dimensions, daily casting volume, demoulding method and the laboratory workflow. Looking at the product name alone is not sufficient for a reliable purchasing decision.</p><h3>Points to verify</h3><ul><li>Confirm the specimen shape and internal dimensions</li><li>Record the product code, material and body weight</li><li>Check the current edition of the referenced method</li><li>Plan cleaning, inspection and spare mould requirements</li></ul><p>Keep the internal surface clean, place and compact concrete according to the applicable procedure, identify the specimen clearly and maintain the required curing conditions. A mould does not determine compressive strength by itself, but damaged geometry, hardened residue or severe wear may affect specimen dimensions and surface quality. Inspect the body and the compressed-air inlet regularly. Do not use hammers, chisels or other impact tools to force the specimen out. If visible distortion or cracking is found, remove the mould from routine use until its condition and internal dimensions have been checked.</p><p>Before ordering, the laboratory and purchasing team should use the same full description. “Concrete specimen mould” alone is ambiguous; state cube or cylinder geometry, exact internal size, product code, body weight and quantity. Verify the latest edition of the sampling, preparation, curing and testing procedures rather than treating general product information as a substitute for a standard. On delivery, check quantity, packaging, visible damage and product identification before use. Laboratories with a high daily casting volume should include spare moulds in their planning so that a damaged unit does not interrupt the specimen programme.</p><p>AYKOMSAN KALIP product pages list size, material, weight and product code separately. For project quantities, include daily use, spare mould requirements, delivery city and requested date so that the quotation can be prepared accurately. Review the <a href="{{u}}kategori/beton-numune-kaliplari">product category</a> or <a href="{{u}}teklif-al">request a quotation</a>.</p>

Is there a price advantage for bulk orders?+

<p><strong>Short answer:</strong> Is there a price advantage for bulk orders? should be answered by checking the current project specification, the referenced test method and the exact mould data. Product selection should consider specimen geometry, target dimensions, daily casting volume, demoulding method and the laboratory workflow. Looking at the product name alone is not sufficient for a reliable purchasing decision.</p><h3>Points to verify</h3><ul><li>Confirm the specimen shape and internal dimensions</li><li>Record the product code, material and body weight</li><li>Check the current edition of the referenced method</li><li>Plan cleaning, inspection and spare mould requirements</li></ul><p>Keep the internal surface clean, place and compact concrete according to the applicable procedure, identify the specimen clearly and maintain the required curing conditions. A mould does not determine compressive strength by itself, but damaged geometry, hardened residue or severe wear may affect specimen dimensions and surface quality. Inspect the body and the compressed-air inlet regularly. Do not use hammers, chisels or other impact tools to force the specimen out. If visible distortion or cracking is found, remove the mould from routine use until its condition and internal dimensions have been checked.</p><p>Before ordering, the laboratory and purchasing team should use the same full description. “Concrete specimen mould” alone is ambiguous; state cube or cylinder geometry, exact internal size, product code, body weight and quantity. Verify the latest edition of the sampling, preparation, curing and testing procedures rather than treating general product information as a substitute for a standard. On delivery, check quantity, packaging, visible damage and product identification before use. Laboratories with a high daily casting volume should include spare moulds in their planning so that a damaged unit does not interrupt the specimen programme.</p><p>AYKOMSAN KALIP product pages list size, material, weight and product code separately. For project quantities, include daily use, spare mould requirements, delivery city and requested date so that the quotation can be prepared accurately. Review the <a href="{{u}}kategori/beton-numune-kaliplari">product category</a> or <a href="{{u}}teklif-al">request a quotation</a>.</p>

Is VAT included in prices?+

<p><strong>Short answer:</strong> Is VAT included in prices? should be answered by checking the current project specification, the referenced test method and the exact mould data. Product selection should consider specimen geometry, target dimensions, daily casting volume, demoulding method and the laboratory workflow. Looking at the product name alone is not sufficient for a reliable purchasing decision.</p><h3>Points to verify</h3><ul><li>Confirm the specimen shape and internal dimensions</li><li>Record the product code, material and body weight</li><li>Check the current edition of the referenced method</li><li>Plan cleaning, inspection and spare mould requirements</li></ul><p>Keep the internal surface clean, place and compact concrete according to the applicable procedure, identify the specimen clearly and maintain the required curing conditions. A mould does not determine compressive strength by itself, but damaged geometry, hardened residue or severe wear may affect specimen dimensions and surface quality. Inspect the body and the compressed-air inlet regularly. Do not use hammers, chisels or other impact tools to force the specimen out. If visible distortion or cracking is found, remove the mould from routine use until its condition and internal dimensions have been checked.</p><p>Before ordering, the laboratory and purchasing team should use the same full description. “Concrete specimen mould” alone is ambiguous; state cube or cylinder geometry, exact internal size, product code, body weight and quantity. Verify the latest edition of the sampling, preparation, curing and testing procedures rather than treating general product information as a substitute for a standard. On delivery, check quantity, packaging, visible damage and product identification before use. Laboratories with a high daily casting volume should include spare moulds in their planning so that a damaged unit does not interrupt the specimen programme.</p><p>AYKOMSAN KALIP product pages list size, material, weight and product code separately. For project quantities, include daily use, spare mould requirements, delivery city and requested date so that the quotation can be prepared accurately. Review the <a href="{{u}}kategori/beton-numune-kaliplari">product category</a> or <a href="{{u}}teklif-al">request a quotation</a>.</p>

How can I check stock and lead time?+

<p><strong>Short answer:</strong> How can I check stock and lead time? should be answered by checking the current project specification, the referenced test method and the exact mould data. Product selection should consider specimen geometry, target dimensions, daily casting volume, demoulding method and the laboratory workflow. Looking at the product name alone is not sufficient for a reliable purchasing decision.</p><h3>Points to verify</h3><ul><li>Confirm the specimen shape and internal dimensions</li><li>Record the product code, material and body weight</li><li>Check the current edition of the referenced method</li><li>Plan cleaning, inspection and spare mould requirements</li></ul><p>Keep the internal surface clean, place and compact concrete according to the applicable procedure, identify the specimen clearly and maintain the required curing conditions. A mould does not determine compressive strength by itself, but damaged geometry, hardened residue or severe wear may affect specimen dimensions and surface quality. Inspect the body and the compressed-air inlet regularly. Do not use hammers, chisels or other impact tools to force the specimen out. If visible distortion or cracking is found, remove the mould from routine use until its condition and internal dimensions have been checked.</p><p>Before ordering, the laboratory and purchasing team should use the same full description. “Concrete specimen mould” alone is ambiguous; state cube or cylinder geometry, exact internal size, product code, body weight and quantity. Verify the latest edition of the sampling, preparation, curing and testing procedures rather than treating general product information as a substitute for a standard. On delivery, check quantity, packaging, visible damage and product identification before use. Laboratories with a high daily casting volume should include spare moulds in their planning so that a damaged unit does not interrupt the specimen programme.</p><p>AYKOMSAN KALIP product pages list size, material, weight and product code separately. For project quantities, include daily use, spare mould requirements, delivery city and requested date so that the quotation can be prepared accurately. Review the <a href="{{u}}kategori/beton-numune-kaliplari">product category</a> or <a href="{{u}}teklif-al">request a quotation</a>.</p>

Do you ship throughout Türkiye?+

<p><strong>Short answer:</strong> Do you ship throughout Türkiye? should be answered by checking the current project specification, the referenced test method and the exact mould data. Product selection should consider specimen geometry, target dimensions, daily casting volume, demoulding method and the laboratory workflow. Looking at the product name alone is not sufficient for a reliable purchasing decision.</p><h3>Points to verify</h3><ul><li>Confirm the specimen shape and internal dimensions</li><li>Record the product code, material and body weight</li><li>Check the current edition of the referenced method</li><li>Plan cleaning, inspection and spare mould requirements</li></ul><p>Keep the internal surface clean, place and compact concrete according to the applicable procedure, identify the specimen clearly and maintain the required curing conditions. A mould does not determine compressive strength by itself, but damaged geometry, hardened residue or severe wear may affect specimen dimensions and surface quality. Inspect the body and the compressed-air inlet regularly. Do not use hammers, chisels or other impact tools to force the specimen out. If visible distortion or cracking is found, remove the mould from routine use until its condition and internal dimensions have been checked.</p><p>Before ordering, the laboratory and purchasing team should use the same full description. “Concrete specimen mould” alone is ambiguous; state cube or cylinder geometry, exact internal size, product code, body weight and quantity. Verify the latest edition of the sampling, preparation, curing and testing procedures rather than treating general product information as a substitute for a standard. On delivery, check quantity, packaging, visible damage and product identification before use. Laboratories with a high daily casting volume should include spare moulds in their planning so that a damaged unit does not interrupt the specimen programme.</p><p>AYKOMSAN KALIP product pages list size, material, weight and product code separately. For project quantities, include daily use, spare mould requirements, delivery city and requested date so that the quotation can be prepared accurately. Review the <a href="{{u}}kategori/beton-numune-kaliplari">product category</a> or <a href="{{u}}teklif-al">request a quotation</a>.</p>

What should be checked upon delivery?+

<p><strong>Short answer:</strong> What should be checked upon delivery? should be answered by checking the current project specification, the referenced test method and the exact mould data. Product selection should consider specimen geometry, target dimensions, daily casting volume, demoulding method and the laboratory workflow. Looking at the product name alone is not sufficient for a reliable purchasing decision.</p><h3>Points to verify</h3><ul><li>Confirm the specimen shape and internal dimensions</li><li>Record the product code, material and body weight</li><li>Check the current edition of the referenced method</li><li>Plan cleaning, inspection and spare mould requirements</li></ul><p>Keep the internal surface clean, place and compact concrete according to the applicable procedure, identify the specimen clearly and maintain the required curing conditions. A mould does not determine compressive strength by itself, but damaged geometry, hardened residue or severe wear may affect specimen dimensions and surface quality. Inspect the body and the compressed-air inlet regularly. Do not use hammers, chisels or other impact tools to force the specimen out. If visible distortion or cracking is found, remove the mould from routine use until its condition and internal dimensions have been checked.</p><p>Before ordering, the laboratory and purchasing team should use the same full description. “Concrete specimen mould” alone is ambiguous; state cube or cylinder geometry, exact internal size, product code, body weight and quantity. Verify the latest edition of the sampling, preparation, curing and testing procedures rather than treating general product information as a substitute for a standard. On delivery, check quantity, packaging, visible damage and product identification before use. Laboratories with a high daily casting volume should include spare moulds in their planning so that a damaged unit does not interrupt the specimen programme.</p><p>AYKOMSAN KALIP product pages list size, material, weight and product code separately. For project quantities, include daily use, spare mould requirements, delivery city and requested date so that the quotation can be prepared accurately. Review the <a href="{{u}}kategori/beton-numune-kaliplari">product category</a> or <a href="{{u}}teklif-al">request a quotation</a>.</p>

Get a Clear Quote for This Product

Our technical team is ready for the best per-unit price and fast delivery.

We use cookies to provide you a better service. Cookie Policy